APPENDIX3 LIST OF SETTINGNUMBERS(Cent’d)
4
“ “: TEST (0)
The usual operation is similar to-case of “0”
SYSTEM. Self-diagnostics of the memorycon-
tents and checking of reference zero return
point are omitted.
Note:
1. Setting the values other than described
above cannot permit the correct operatiorl.
2. Setting can be effective only when the
system number switch provided on the upper
part of the unit is set at “O.”
[4 C’L’p 1
XSL2P, ZSL2P:
Sets the boundary area in positive direction
of Stored Stroke Limit seco:nd prohibit area on
X-axis and Z-axis, respectively.
Set l,ing range: O to + 99999999
Setting: Least output increment
[- CXSL2M 1
I
#6503
II
ZSL2M
1
L-----J L—_————
J
Ml
ZSL3P
_--l
XSL3P, ZSL3P:
Sets the boundary area in positive direction
of Stored Stroke Limit third prohibit area on
X-axis and Z-axis, respectively.
Setting range:
o
to f 99999999
Setting: Least output increment
I
#6506
II
XSL3M
I
L
1
I
#6507
II
ZSL311
I
,
XSL3M,ZSL311:
Sets the boundary area in minus direction of
Stored Stroke Limit third prohibit area on
X-axis and Z-axis, respectively.
Setting range: O to t 99999999
Setting: Least output increment
XSL2M,ZSL2M:
Sets the boundary area in minus direction of
Stored Stroke Limit second prohibit area on
X-axis and Z-axis, respectively.
Setting range:
o
to t 99999999
Setting: Least output increment
--108-