2.2.5 Instrument Information
Commands
Command Description Page
_MFG
Outputs the instrument
manufacturer
2-115
_INF
Outputs the instrument’s product
name
2-115
_COD
Outputs the instrument’s basic
specifications
2-115
_VER
Outputs the instrument’s firmware
version information
2-115
_OPT
Outputs the instrument’s option
installation information
2-115
_TYP
Outputs the instrument’s
temperature unit, and daylight
saving time installation information
2-115
_ERR
Outputs the instrument’s error
number information
2-115
_UNS
Outputs the instrument’s unit
configuration information
2-115
_UNR
Outputs the instrument’s unit
configuration information
2-115
_MDS
Outputs the instrument’s module
configuration information
2-115
_MDR
Outputs the instrument’s module
configuration information
2-115
2.2.6 Conditions for Executing
Commands
A command can be executed only when the recorder can
execute the setting change or operation that the command
specifies. Commands are invalid in the following
circumstances.
• The recorder is not in a condition to accept the
operation.
For example, if the recorder is not recording, you
cannot write a message.
• If the recorder does not have the function or is not
using the function.
The “Description” column in section 2.2.1, “Setting
Commands” contains the recorder suffix codes that are
required for using the commands.
• If the login function is in use, the command cannot be
used at the user level that the user is logged in at.
• User restriction is placed on the operation.
The following table lists the commands that are invalid
according to the limitation types (p1 of the SOpeLimit
command or p2 of the SUserLimit command).
Limitation Type Invalid Command
Memory ORec
Math OMath
DataSave OExecRec, OMTReset
Message OMessage
Batch OBatName, OBatComment,
OBatText
AlarmACK OAlarmAck
Comm OEMail, OIPApply,
OMBRestore, OSLMPRestore
DispOpe SHomeKind, SHomeMonitor,
SFavoriteKind,
SFavoriteMonitor, Smonitor,
SMultiPattern, SMultiKind,
ODispRate
DateSet OExecSNTP, OSetTime
ChangeSet
Sxxxx
*1
, OLoadConf,
OLoadConfAll, Oinit
*3
OCtrlLoadPAT,
OCtrlLoadPATAll
File OLoadConf, OLoadConfAll,
OSaveConf, OSaveConfAll,
OCtrlLoadPAT, OCtrlSavePAT,
OCtrlLoadPATAll,
OCtrlSavePATAll, Fmedia
System OInit, FSysConf (when p1
is specified)
Out OCmdRelay, OCommCh
CalibSet
*2
SCalibIO, SSchedule,
SScheduleText,
OLoadConfAll, OLoadConf
*4
,
OInit
*5
ControlIN OCtrlRL
ControlOUT OCtrlSR, OCtrlAM, OCtrlMO
Tuning OCtrlAT
Program OCtrlMODE, OCtrlHOLD,
OCtrlADV
*1 Setting commands except for SHomeKind, SHomeMonitor,
SFavoriteKind, SFavoriteMonitor, Smonitor, SMultiPattern,
SMultiKind, and SCalibIO
(Note)
(Note) Only when the advanced security function (/AS option)
is in use on instruments whose version is 2.02 or later.
*2 Can be specified with the SUserLimit command when
the advanced security function (/AS option) is in use on
instruments whose version is 2.02 or later.
*3 Cannot be executed if initialization items include
SECURITY or OTHERS items.
*4 Cannot be executed if load items include CALIB items.
*5 Cannot be executed if initialization items include CALIB
items.
• The command is not applicable to the model.
For commands that can be used only on certain
models, the models are listed in the “Description”
column in section 2.2.1, “Setting Commands,” to
section 2.2.4, “Communication Control Commands.”
(Examples: [GX/GP], [GM])
The applicable models for the following commands are
further reduced.
Command Applicable Models
SViewAngle
GX10, GP10
SMultiPattern
GX20, GP20
SMultiKind
GX20, GP20
2.2 List of Commands