Page #152 background image
2-134
IM 04L51B01-17EN
2.10.9 Alarm Summary (FLog)
The output in response to the command “FLog,ALARM” is shown below.
Syntax
EA<crlf>
yyyy/mo/dd_hh:mm:ss.ttt_kkk_cccc_lss<crlf>
EN<crlf>
yyyy/mo/dd_hh:mm:ss.ttt Time of alarm occurrence
yyyy
Year (1900 to 2099)
mo
Month (01 to 12)
dd
Day (01 to 31)
hh
Hour (00 to 23)
mm
Minute (00 to 59)
ss
Second (00 to 59)
ttt
Millisecond (000 to 999)
A period is inserted between the minute and
millisecond.
kkk
Alarm cause
OFF
Alarm release
ON_
Alarm occurrence
ACK
All channel alarm ACK, Individual alarm
ACK
ALL
All channel alarm OFF
cccc
Channel number (set to four spaces if the alarm cause is
“ACK” or “ALL”)
l
Alarm level (1 to 4)
ss
Alarm type
H_
High limit alarm
h_
Difference high limit alarm
L_
Low limit alarm
l_
Difference low limit alarm
R_
High limit on rate-of-change alarm
r_
Low limit on rate-of-change alarm
T_
Delay high limit alarm
t_
Delay low limit alarm
If the cause of alarm is “all channel alarm ACK” or “all channel alarm OFF,” the channel
number, alarm level, and alarm type will be blank.
If the cause of alarm is “individual alarm ACK,” the alarm type will be blank.
2.10 ASCII Output Format

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA GX10 and is the answer not in the manual?

YOKOGAWA GX10 Specifications

General IconGeneral
BrandYOKOGAWA
ModelGX10
CategoryVoice Recorder
LanguageEnglish

Related product manuals