2-8
IM 04L51B01-17EN
SCtrlCalc
Reference source of EXPV
and RSP
2-83
SCtrlFilterSP
Remote SP filter 2-83
SCtrlRatioSP
Remote SP ratio 2-83
SCtrlBiasSP
Remote SP bias 2-83
SCtrlErrPreOut
Preset output value for input
errors
2-83
SCtrlOutLimit
Releasing of the output limiter
function in manual mode
2-84
Control Operation Parameter Setting Commands
SCtrlAlarm
Control alarm 2-84
SCtrlAlarmVal
Control alarm value 2-84
SCtrlSP
Target setpoint 2-85
SCtrlSPGradient
Target setpoint ramp-rate 2-85
SCtrlPIDNo
Target setpoint PID group
number
2-85
SCtrlRefPoint
Zone PID setting 1
reference point
2-85
SCtrlRHys
Zone PID setting 2
switching hysteresis
2-85
SCtrlRefDEV
Zone PID setting 3
reference deviation
2-86
SCtrlPIDPb
PID parameter setting 1
Proportional band
2-86
SCtrlPIDTI
PID parameter setting 2
Integration time
2-86
SCtrlPIDTD
PID parameter setting 3
Derivative time
2-86
SCtrlPIDPara
PID parameter setting 4
Control parameters
2-86
SCtrlRefPb
Reference PID setting 1
Proportional band
2-87
SCtrlRefTI
Reference PID setting 2
Integration time
2-87
SCtrlRefTD
Reference PID setting 3
Derivative time
2-87
SCtrlRefPara
Reference PID setting 4
Control parameters
2-87
SCtrlDetail
Control detail setting 1
Tracking, setpoint limit, ramp-
rate time unit
2-88
SCtrlOutRatio
Control detail setting 2
Output velocity limiter
2-88
SCtrlAtDetail
Control detail setting 3
Auto-tuning details
2-88
SCtrlAntiReset
Control detail setting 4
Over-integration suppressing
function
2-88
SCtrlOvershoot
Control detail setting 5
Control output suppressing
function (overshoot-
suppressing function)
2-89
Control Display Setting Commands
SCtrlGroupSW
Control group use On/Off 2-89
SCtrlGroupName
Control group name 2-89
SCtrlGroupSplit
Control group divisions [GX/
GP]
2-89
SCtrlGroup
Loop to assign to control
group
2-89
SCtrlTag
Loop tag, tag comment 2-90
SCtrlDispDV
Deviation display band 2-90
SCtrlBackColor
Background color [GX/GP] 2-90
SCtrlOutOperate
OUT value manual output
operation type
2-90
STagIO
PID control module channel
display (tag, tag No.)
2-29
SColorIO
PID control module channel
display (color)
2-29
SZoneIO
PID control module channel
display (zone high limit, zone
low limit)
2-30
SScaleIO
PID control module channel
display (scale display position,
number of scale divisions)
2-30
SBarIO
PID control module channel
display (bar display position,
number of bar divisions)
2-30
SPartialO
PID control module channel
display (partial)
2-30
SValueIO
PID control module channel
display (upper and lower limit
string)
2-31
Program Control Setting Commands
SPrgColor
Loop color 2-91
SPrgDispDetail
Auto message printing,
screen switching
2-91
Control Event Action Setting Commands
SCtrlEventAct
Control event action 2-91
Logic Math Setting Commands
SLogicMath
Logic math expression 2-93
SWConst
Variable constant 2-93
2.2.2 Output Commands
Command Description
(Required Options)
[Applicable Models]
Page
FData
Outputs the most recent channel
data
2-94
FRelay
Outputs the most recent relay
and internal switch status
2-94
FTransStatAO
Outputs the most recent re-
transmission (AO channel) status
2-94
FFifoCur
Outputs channel FIFO data 2-94
FSnap
Takes a snapshot [GX/GP] 2-95
FUser
Outputs the user level 2-95
FAddr
Outputs the IP address 2-95
FStat
Outputs the GX/GP status 2-95
FLog
Outputs the log 2-95
FEventLog
Outputs a detail event log (/AS) 2-96
FMedia
Outputs external storage medium
and internal memory information
2-96
FCnf
Outputs setting data 2-97
FChInfo
Outputs decimal place and unit
information
2-98
FSysConf
Queries the system configuration
and reconfigures modules
2-98
FBTDevInfo
Bluetooth device information
output (/C8) [GM]
2-98
FReminder
Outputs reminder information (/
AH)
2-98
FCtrlData
Control data output 2-98
FCtrlNo
SP number and PID number
output
2-99
FCtrlMode
Control mode output 2-99
FPrgMode
Program operation mode output
(/PG)
2-99
FPrgPtnInfo
Program pattern information
output (/PG)
2-99
2.2 List of Commands