11
All Rights Reserved. Copyright © 2012, Yokogawa Electric Corporation
GS 04L51B01-01EN
Nov. 10, 2015-00
• Conguringscreens:Screencreationsoftware
CreationusingDXA170DAQStudio(GXdoes
nothaveacreationfunction)
• Saving/loadingscreendata:
Aspeciedscreenorallthescreensis/are
loadedfromanexternalstoragemediumtothe
internalmemory,oraspeciedscreenorallthe
screens in the internal memory is/are saved on
anexternalstoragemedium.
VGAVIDEOOUTPUT(/D5)(OnlyforGX20)
• Externaldisplay:
Resolution:800×600dots(VGA)
Connector:15-pinD-Sub(female)
EtheNet/IPCOMMUNICATION(PLC
communicationprotocol)(/E1)
CanbejoinedtoanEthernet/IPnetworkasan
adapter (or a server).
• LoadingdatafromtheI/Ochannelorcalculation
channel (/MT)
I/Ochannel:
GX10: 100, GX20-1: 100, GX20-2: 500
Calculation channel:
GX10: 50, GX20-1: 100, GX20-2: 100
• Loadingandwritingdatafrom/tothe
communication channel (/MC)
Communication channel:
GX10: 50, GX20-1: 300, GX20-2: 500
WTCOMMUNICATION(/E2)
CollectsdatabyconnectingtoWTequipment
manufacturedbyYokogawaMeters&Instruments
Corp. via Ethernet communication.
• Supportedmodels:WT1800,WT500,and
WT300
• Numberofconnectableunits:
GX10: 8
GX20: 16
• Communicationcycle:500ms/1s/2s/5s/10s/20
s/30 s
• Typesofdatathatcanbeobtained:Voltage,
current,power,powerfactor,phase,electrical
energy,high-frequencywave,etc.
• Numberofdataallocations
GX20300
GX1050
FAILOUTPUT(/FL)
• Contact:Ccontact,1point
• FAILoutput:
The relay contact output on the rear panel
indicatestheoccurrenceofCPUfailure.
Relay operation: Energized during normal
operationandde-energizedonCPUfailure.
• Statusoutput:Therelaycontact,whichisde-
energized in normal output state, is energized
upontheoccurrenceofamemory/mediaerror,
measurement error, communication error,
recording stop, or alarm.
• Ratedpowersupplyvoltage:24VDCor250V
ACorless
• Ratedloadcurrent:3A(DC)/3A(AC),resistance
load
• Min.loadcurrent:100mA
• Recommendedreplacementperiodsofcontact:
Electrical:30,000moreON-OFFoperations,
Mechanical:5,000,000moreON-OFFoperations
LogSCALE(/LG)
Alogarithmicvoltagethathasbeenconvertedfrom
a physical value is applied to the GX, and then the
GX’sLogscale(logarithmicscale)isusedtodisplay
and record the physical value.
• Inputtype:Loginput(logarithmicinput),Pseudo
loginput:Aninputthatsupportspseudo
logs,Loglinearinput:Inputthatislinearona
logarithmic scale.
• Range:20mV/60mV/200mV/1V/2V/6V/20V/50V
• Scalablerange:
• Loginput:
1.00E-15to1.00E+15(15decade
maximum)
Scale_L<Scale_U
Ifthelowerlimitmantissais1.00,the
differencebetweentheexponentsmustbe
1 or more.
Ifthelowerlimitmantissaisavalueother
than1.00,thedifferencebetweenthe
exponentsmustbe2ormore.
• PseudoLogInput/Loglinearinput
1.00E-15to1.00E+15(15decade
maximum)
The higher limit mantissa is the same as
the lower limit mantissa).
Ifthelowerlimitmantissais1.00,thevalue
mustbebetween1.00E–15and1.00E+15,
thedifferencebetweentheexponentsmust
be1ormore,andthemaximumdecadesis
15.
Ifthelowerlimitmantissaisavalueother
than 1.00, the value must be between
1.01E–15and9.99E+14,thedifference
betweentheexponentsmustbe1ormore
andthemaximumdecadesis15.
• Alarmtype:Highlimit,lowlimit,delayhighlimit,
and delay low limit
• Alarmsettingrange:Therangeconvertedinto
theLOGscalecorrespondingto-5%to105%of
the span width.
• Alarmhysteresis:Fixedto0
• Greenbandsettingrange:Thelowerlimittothe
upperlimitofthescale.However,thelowerlimit
ofthedisplaypositionmustbesmallerthanthe
upper limit.
• Positionofthedecimalpoint:1to2
• Misc:Nonlinearinputispossiblebycorrecting
the input value

Table of Contents