13-9
IM 760401-01E
Communication Commands 1 (System of Commands before the IEEE 488.2-1987 Standard)
13
OH/OH? Sets communication output information
types in case of harmonic measurement/
inquires about the current settings.
Syntax OH m1,m2 <terminator>
“m1” indicates output type no.
• in case of print mode
m1= 1: (V) outputs measured
voltage value and relative
harmonic content as a
numerical value
2: (A) outputs measured
current value and relative
harmonic content as a
numerical value
3: (W) outputs measured
active power value and
relative harmonic content
as a numerical value
4: (deg) outputs the phase
angle as a numerical value
5: (GV) outputs measured
voltage value as numerical
value and graph
6: (GA) outputs measured
current value as numerical
value and graph
7: (GW) outputs measured
active power value as
numerical value and graph
8: (GVD) outputs the phase
angle between the 2nd to
50 (or 30) th order
voltage and the
fundamental (1st order) as
numerical value and graph
9: (GAD) outputs the phase
angle between the 2nd to
50 (or 30) th order
current and the
fundamental (1st order) as
numerical value and graph
10:(CGV) outputs the relative
harmonic content of
voltage as numerical value
and graph
11:(CGA) outputs the relative
harmonic content of
current as numerical value
and graph
12: (CGW) outputs the relative
harmonic content of active
power as numerical value
and graph
13: (ALL) outputs the relative
harmonic content and
measured value of both
voltage and current
• in case of any other mode
m1= 1: (V) outputs measured
voltage value and relative
harmonic content as a
numerical value
2: (A) outputs measured
current value and relative
harmonic content as a
numerical value
3: (W) outputs measured
active power value and
relative harmonic content
as a numerical value
4: (deg) outputs the phase
angle between the first
order voltage(current) and
the 2nd to 50 (or 30) th
voltage(current) as a
numerical value
5: (GV) outputs measured
voltage value and relative
harmonic content as
numerical value
6: (GA) outputs measured
current value and relative
harmonic content as
numerical value
7: (GW) outputs measured
active power value and
relative harmonic content
as numerical value
8: (GVD) outputs the phase
angle between the first
order voltage(current) and
the 2nd to 50 (or 30) th
voltage(current) as a
numerical value
9: (GAD) outputs the phase
angle between the first
order voltage(current) and
the 2nd to 50 (or 30) th
voltage(current) as a
numerical value
10: (CGV) outputs the measured
value of voltage and
relative harmonic content
as numerical value
11: (CGA) outputs the measured
value of current and
relative harmonic content
as numerical value
12: (CGW) outputs the measured
value of active power and
relative harmonic content
as numerical value
13.1 Commands

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA WT210 and is the answer not in the manual?

YOKOGAWA WT210 Specifications

General IconGeneral
BrandYOKOGAWA
ModelWT210
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals