ZPL Configuration
131
From this point in the Configuration Receipt listing, the printout has sensor settings and values displayed to
troubleshoot sensor and media operations. These are typically used by Zebra Tech Support to diagnose
printer problems.
** - Not supported with a ZPL command, uses the Set Get Do command in the ZPL manual. See
device.command_override.xxxxx in the ZPL Programmer’s manual.
1. ZPL Commands and Configuration Report Callout Cross-Reference
Command Listing Name Description
~SD
DARKNESS Default: 10.0
^PR
PRINT SPEED Default: 101.6 mm/s / 4 IPS
152.4 mm/s / 6 IPS (max.) — ZD230 only
~TA
TEAR OFF Default: +000
^MN
MEDIA TYPE Default: GAP/NOTCH
SENSOR SELECT Default: AUTO (
^MNA - Auto-Detect)
^MT
PRINT METHOD THERMAL-TRANS or DIRECT-THERMAL
^PW
PRINT WIDTH Default: 832 (dots for 203 dpi)
^LL
LABEL LENGTH Default: 1230 (dots) (dynamically updated while printing)
^ML
MAXIMUM LENGTH Default: 39.0IN 989MM
—
USB COMM. Connection Status: Connected / Not Connected
— SGD —**
COMMUNICATIONS Default: NORMAL MODE
^CT / ~CT
CONTROL CHAR Default: <~> 7EH
^CC / ~CC
COMMAND CHAR Default: <^> 5EH
^CD / ~CD
DELIM./CHAR Default: <,> 2CH
^SZ
ZPL MODE Default: ZPL II
— SGD —**
COMMAND OVERRIDE Default: INACTIVE
^MFa
MEDIA POWER UP Default: NO MOTION
^MF,b
HEAD CLOSE Default: FEED
~JS
BACKFEED Default: DEFAULT
^LT
LABEL TOP Default: +000
^LS
LEFT POSITION Default: +0000
REPRINT MODE Default: DISABLED