801910 - Zip Sparkling HydroTap - Installation Instructions - July 2014 - V1.00 Page 37 of 40
Commissioning
Procedure:
•
Shield the HydroTap from any direct sun light,
using a dark cloth.
•
With the unit in Normal operating mode
•
Turn the power OFF
•
Pull both tap levers to the forward position
•
Turn ON the power
•
The unit will calibrate the safety switch
•
Return the levers to the neutral position.
Light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the
time of the installation.
All direct natural sun light must be shaded from the HydroTap, during the calibration. This can be achieved by
closing any nearby curtains, blinds, etc.
Pull both levers
forward
Safety
sensor
7.5- Safety Sensor Calibration (Boiling models)
Disable
Booster
10:30 Wed 14, Nov 2013
BC Sparkling
Zip
1. Press the [MENU] button for main menu.
2. Press the [Install] button.
3. Press the [Booster] button.
4. In the next screen, press button to enable the
Booster.
5. Water must be run through the Booster for a min of 30
seconds, before the heater will activate.
6. Dispense boiling water for 30secs and check the Boost-
er outlet hose is warm when the boiling water tank is
replenishing.
Enable
NOTE: For any subsequent fi lter changes or any operational procedures, please refer to the HydroTap user
guide, located inside the fi lter housing access door.