SW3
GIGABIT/FAST ETHERNET SWITCH TYPE SW3 (DIN) 75/122
USER GUIDE - M0SW3D1905Iv04 - V04 May 2019
• On max. reached. This sets the behaviour of the equipment in the event of reaching
the maximum number of MAC addresses permitted, as set in the preceding
parameter. The available options are replace or restrict.
FIGURE 42 Security main menu configuration page
5.15.1 802.1x
This submenu permits specifying the 802.1x user authentication through access to a
RADIUS server.
The general configuration parameters are the following:
• Enable. A simple CheckBox parameter to set if the RADIUS client, as well as the
802.1x authentication, is active or not.
• Periodic reauthentication (reAuthEnable). If the RADIUS server limits the session
time, this option indicates to the equipment that periodic reauthentication has to be
requested.
• Reauthentication period (reAuthPeriod). It sets the time between one
reauthentication and the next. The parameter is expressed in seconds, and the
accepted value range is between 1 and 86400 (1 day), where the default value is
3600 (1 hour).