20 2.8-inch Linux Visible Light Product User Manual
IP Address
The factory default value is 192.168.1.201. Please adjust them according to the
actual network situation.
Subnet Mask
The factory default value is 255.255.255.0. Please adjust them according to the
actual network situation.
DNS
The factory default address is 0.0.0.0. Please adjust them according to the actual
network situation.
TCP COMM. Port
The factory default value is 4370. Please adjust them according to the actual
network situation.
DHCP
Dynamic Host Configuration Protocol, which is to dynamically allocate IP
addresses for clients via server.
To set whether to display the network icon on the status bar.
5.2 PC Connection
To improve the security of data, please set a Comm Key for communication between the device and the PC.
If a Comm Key is set, this connection password must be entered before the device can be connected to the PC
software.
Select PC Connection on the Comm. Settings interface.
The default password is 0, which can changed. The Comm Key may contain1-6 digits.
Device ID
Identity number of the device, which ranges between 1 and 254. If the
communication method is RS232/RS485, you need to input this device ID in the
software communication interface.