5. Basic Operating Instruction
5-3-3 About Hot Keys
Among the Hot Keys (4), the
following 6 parameters are registered for
their frequent usage:
5 Sewing Speed (Parameter code
No.01)
6Length of Lockstitch Sewing at
Buttonhole (Parameter code No.02)
7Pitch of KnifeParameter code
No.03
8 Distance between Stitch Form
(Parameter code No.04)
9 Stitch Number at Eyelet Part
Parameter code No.05
10Length of Bar-tacking (Parameter
code No.06No.08No.10)
Note: The different bar-tacking
sewing types set in parameter code
No.40 are corresponding to the various
values of bar-tacking sewing length
parameter (10).
5-3-4 List of Pattern Parameters at S le
vel
According to the set content of other parameters, the default value of some parameters may be
unchangeable or invalid.
Parameter
Code
Content Range Unit
Default
Value
S01
Sewing Speed
1000~2700rpm 100 1800rpm
S02
Length of Lockstitch Sewing
at Buttonhole
5~50mm 0.5 25mm
S03
Pitch of Knife
-2.5~0.5mm 0.05 0.2mm
S04
Distance between Stitch Form
0.5~2.0mm 0.1 1.0mm
S05
Stitch Number at Eyelet Part
4~20 1 9 Stitches
S06
Length of Taper
1~20mm 1 6mm
S07
Offset
0.5~2.0mm 0.1 1.5mm