7. Interface of Parameter Setting Mode
No. Functions Description Range Changing Default
Step Setting
delay of trimming upper thread is
set, the leftover upper thread may
be increase after sewing.
U556
Time for loosing
upper thread
The larger value, the longer the
time for loosing upper thread after
thread-trimming.
0~100 2ms 50
U557
Upper
thread-loosing Off
Sequence
0~100:the larger value is, the later
the thread-loosing OFF time after
trimming will be.
0~100 2ms 50
U558
Forbid to use
bottom thread
trimmer device
0:OFF
General Conditions (Bottom
thread trimmer device is
activated)
1:ON
Forbid to use bottom thread
trimmer device
0~1 1 0
U559
Neglect of bottom
thread knife
sensor and counter
0:OFF
Detect the bottom thread knife
device is off according to the OFF
sensor of bottom thread trimmer
5~50:Detect the bottom thread
knife device is off according to
time. Set this parameter with a
step at 5ms
0~50 5ms 30
U560
Bottom
thread-trimming
time
0~100:the larger value is, the later
the thread-trimming time will be.
0~100 1 0
U561
Upper
thread-breakage
sensor
0:OFF Device Invalid
1:ON Device Valid
0~1 1 0
U562
Start stitch number
before upper
thread-breakage
sensor
1~9:Sew the set stitches before the
upper thread-breakage detection.
1~9 1 5
U563
Upper
thread-breakage
judging stitch
number
2~7 : When the thread-breakage
signal turns ON at the set stitches ,
the Error of thread-breakage will be
activated.
2~7 1 4
U564
Upper
thread-catching
device
0:OFF Device Invalid
1:ON Device Valid
0~1 1 0
U565
Upper
thread-catching
close time
correction
-10~10: the larger value is, the
later the upper thread-catching will
be
-10~10 1 0
U576
Upper
thread-catching
open time
5~20ms:set in unit of 1ms
5~20 1 10
U577
Frame-moving
Method
0~5:select different frame-moving
method
0~5 1 4
U578
Frame-moving
adjustment 1
-50~50:Adjust the XY
frame-moving angle
-50~100 1 0
U579
Z axis
frame-moving
adjustment
-50~50:Adjust Z axis
frame-moving angle
-50~50 1 0