42
I CLS
-
LMI
-
Calibration
I
ENGLISH
when the command line back at the 0 calibration is finished.
WEIGHT CALIB. 0
Lift Weight 2.60
STEP 8:
unload the weight . Check on the screen the hook weight value (that the
system has calculate); if this value isn’t correct, you have to repeat STEP 5.
When you finish this check, you have to lift the weight and check that the value
of the weight is correct. If this the value is not correct, you have to repeat the
STEP 7.
Continue to verify until you don’t see the right value of the weight.
STEP 9:
move down the boom around 30°; repeat the same operations from STEP 4.
STEP 10:
when you finish this step at this angle, you have to jump at the next boom
length (17.2m).
When you have put the boom length at the next length you have to repeat all
steps (from STEP 3 to STEP 9).
Weight calibration will be finished, when you will finish all boom length.
STEP 11:
You have to save the calibration with the “SAVE” menu.