Alarm Codes
I
45
6 Calculation value of the
boom length sensor 1 lower
than the minimum threshold
Verify that the cable or the connector wiring is
not broken
If the alarm persists, please, contact Technical Assistance :
Verify the length transducer integrity
7 Calculation value of the
boom length sensor 1 higher
than the maximum threshold
Verify that the cable or the connector wiring are
not in short circuit
If the alarm persists, please, contact Technical Assistance :
Verify the pressure transducer integrity.
8 Analogical value of pressure
transducer (bottom side n.1)
lower than the minimum
threshold
Verify that the cable or the connector wiring are
not damaged
If the alarm persists, please, contact Technical Assistance :
Verify the pressure transducer integrity.
9 Analogical value of pressure
transducer (bottom side n.1)
higher than the maximum
threshold
Verify that the cable or the connector wiring are
not in short circuit
If the alarm persists, please, contact Technical Assistance :
Verify the pressure transducer integrity.
10 Analogical value of pressure
transducer (rod side) lower
than the minimum threshold
Verify that the cable or the connector wiring are
not damaged
If the alarm persists, please, contact Technical Assistance :
Verify the pressure transducer integrity.
11 Analogical value of pressure
transducer (rod side) higher
than the maximum threshold
Verify that the cable or the connector wiring are
not in short circuit
If the alarm persists, please, contact Technical Assistance :
Verify the pressure transducer integrity.
12 Analogical value of pressure
transducer (bottom side n.2,
if present) lower than the
minimum threshold
Verify that the cable or the connector wiring are
not damaged
If the alarm persists, please, contact Technical Assistance :
Verify the pressure transducer integrity.
13 Analogical value of pressure
transducer (bottom side n.2,
if present) higher than the
maximum threshold
Verify that the cable or the connector wiring are
not in short circuit
If the alarm persists, please, contact Technical Assistance :
Verify the pressure transducer integrity.