46
I CLS
-
LMI
-
Calibration
I
ENGLISH
14 Internal alarm of
Angle/boom-length sensor
ACT
Contact Technical Assistance
18
Internal error CAN-BUS ACT
Verify the Angle/Boom-length sensor integrity
Verify the connecting cable integrity
If the alarm persists, please, contact Technical Assistance
30
Congruency Alarm of the
system’s output
Reboot your system
Contact Technical Assistance
31
Overload 110%
Release the lifting load
Perform safety operation for having higher lifting
duty
32
Overload 115%
Release the lifting load
Perform safety operation for having higher lifting
duty
33
Overload 120%
Release the lifting load
Perform safety operation for having higher lifting
duty
40 CRC Error of program
Contact Technical Assistance
41 CRC Error of load charts
Contact Technical Assistance
42 CRC Error of program
execution
Contact Technical Assistance
50 LMI By-pass key is activated
Pay attention to machine operation.