88 CHAPTER 5: SOFTWARE INSTALLATION AND CONFIGURATION UNDER WINDOWS 3.X
5 When the NIC Configuration dialog box is displayed,
select Modify and press Enter.
The I/O Base Address field is selected. An I/O Base Address
dialog box appears.
6 Use the arrow key to select EISA and press Enter.
The I/O base address setting is changed.
7 Select OK to save the new configuration setting and
press Enter.
8 Exit the program and remove EtherDisk diskette 2
from drive A.
9 Insert the EISA configuration utility diskette provided
with your PC in drive A.
10 Turn the power off. Wait 10 seconds, and then turn
the power on.
11 Follow the instructions accompanying your EISA PC to
run the EISA Configuration Program.
When the program prompts you for .CFG files to copy,
insert EtherDisk diskette 2, press Enter, and select the
appropriate file for your NIC as shown in Table 7:
If you are prompted for the wrong !TCM file:
a Turn the power off and remove the NIC.
b Clean the edge connectors on the NIC.
c Reinsert the NIC in the slot. Make sure the NIC is fully
seated in the slot.
d Turn the power on.
You should now be prompted for the correct !TCM file.
Table 7 EISA Configuration Programs
For this NIC... Select this .CFG file
3C509B-COMBO !TCM5094.CFG
3C509B-TP !TCM5090.CFG
3C509B-TPO !TCM5095.CFG
3C509B-TPC !TCM5098.CFG
Book Page 88 Monday, June 7, 1999 8:55 AM