EasyManuals Logo

3M MS2 User Manual

3M MS2
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
23
6.9 Bridge Splicing Using 4005-DPM Super-Mate
to an Inline 4000-D Super-Mini Splice
893742
Note: A stripped splice head may be used with a crimper instead of hand tools.
4270-A Hand Presser
6.9.1 PIC Cable
6.9.1.1Preterminate Super-Mate Module, then plug
to corresponding groups.
6.9.2 Pulp Cable
6.9.2.1Tag modules that receive stub count using
4079-S Tagging Labels.
6.9.2.3Begin pretermination stub by removing
tagging label from module in splice and
placing it on the tape plate of splicing head.
Immediately identify module from which
tagging label was removed by marking the
pair number on each end of the cover.
893742
76586
781259
6.9.2.4Preterminate Super-Mate Module, then plug
to corresponding groups according to label.
Pair numbers on
each end of cover
Move label to
tape plate
76579
6.9.2.2Access with 4047 or 4048 Test Probe.
BRIDGE
FIELD
Note: Free conductor 2 times
length of splice opening.
4005-DPM
4000-D
4000-D
C.O.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 3M MS2 and is the answer not in the manual?

3M MS2 Specifications

General IconGeneral
Brand3M
ModelMS2
CategoryPower Tool
LanguageEnglish

Related product manuals