8.11 Cable Transfer – Conductor Termination
New cable – New conductor groups involved with a transfer must be terminated in Super-Mate Modules
according to 3M MS
2
Splicing Procedures and local transfer plan.
Existing splices – If these existing groups are terminated in anything other than a Super-Mate Module,
they must be converted to Super-Mate Modules in numerical sequence or color code order.
Lay pairs into Super-Mate Modules. Make sure that all existing C.O. and FIELD conductors are placed in
corresponding wire channels in each Super-Mate Module.
FIELD
C.O
.
Cover
Body
Insulator
Body
843060