8.6.5.3Maximum Bundle Size for Closures
8.6.5.3.1 26 AWG Two Bank Straight Splice*
Main Cable
Pair Count Zero 100 200 300 400 600 900 1200 1500 1800 2100 2400 2700 3000
100 1.3 1.7
200 1.9 2.1 2.4
300 2.2 2.6 2.7 3.0
400 2.6 2.9 3.0 3.2 3.7
600 3.1 3.4 3.5 3.8 4.1 4.4
900 3.8 4.0 4.2 4.4 4.7 4.9 5.3
1100 4.0 4.4 4.6 4.8 5.0 5.1 5.6
1200 4.2 4.5 4.8 5.0 5.2 5.3 5.8 6.3
1500 4.9 5.1 5.4 5.6 5.7 6.0 6.3 6.7 7.0
1800 5.4 5.6 5.9 6.0 6.1 6.4 6.6 7.1 7.3 7.6
2100 5.8 6.1 6.3 6.4 6.5 6.8 7.2 7.5 7.6 7.9 8.3
2400 6.2 6.5 6.7 6.8 6.9 7.2 7.6 7.9 7.9 8.2 8.6 8.8
2700 6.6 7.0 7.1 7.2 7.3 7.6 7.8 8.2 8.3 8.6 8.9 9.4 9.6
3000 7.0 7.4 7.5 7.6 7.7 8.0 8.3 8.6 8.6 8.9 9.3 9.8 10.1
3600 7.7 8.2 8.3 8.4 8.5 8.7 9.0 9.1 9.2 9.6 9.9 10.3 10.6 10.9
Straight Splice Measurement in Inline Configuration
(4000-D Super-Mini Modules)
Number of Pair Bridged
(4000-D Super-Mini and 4005-DPM Super-Mate Modules)
VALUES IN INCHES
*NOTE: For 22 AWG conductors, increase values by 25%
For 24 AWG conductors, increase values by 12%
If sealant boxes are used, increase values approximately 25%
Main Cable
Pair Count Zero 100 200 300 400 600 900 1200 1500 1800 2100 2400 2700 3000
300 1.8 2.1 2.4 2.7
600 2.6 2.8 3.1 3.3 3.4 3.7
900 3.3 3.5 3.8 4.0 4.1 4.3 4.8
1200 3.9 4.1 4.3 4.5 4.7 5.0 5.5 5.7
1500 4.5 4.6 4.7 4.9 5.1 5.5 5.9 6.3 6.6
1800 5.1 5.2 5.3 5.4 5.5 5.9 6.3 6.7 7.0 7.3
2100 5.5 5.6 5.7 5.8 5.9 6.3 6.7 7.0 7.4 7.7 7.8
2400 5.9 6.0 6.1 6.2 6.3 6.6 7.0 7.3 7.7 8.0 8.1 8.4
2700 6.2 6.3 6.4 6.5 6.6 6.9 7.2 7.6 8.0 8.3 8.5 8.7 8.8
3000 6.5 6.6 6.7 6.8 6.9 7.2 7.5 7.9 8.2 8.6 8.7 9.0 9.1 9.3
3600 6.9 7.0 7.1 7.2 7.3 7.6 7.9 8.3 8.6 8.9 9.2 9.4 9.5 9.7
Straight Splice Measurement in Inline Configuration
(4000-D Super-Mini Modules)
Number of Pair Bridged
(4000-D Super-Mini and 4005-DPM Super-Mate Modules)
8.6.5.3.2 26 AWG Three Bank Straight Splice*
VALUES IN INCHES
*NOTE: For 22 AWG conductors, increase values by 25%
For 24 AWG conductors, increase values by 12%
If sealant boxes are used, increase values approximately 25%