DECT Measuring Device ME-8 (test kit)
56
Planning Aastra 400 DECT systems as of R1.0
syd-0457/1.0 – R1.0 – 10.2012
Detail Display of ”Connection Quality
Pressing the ”i” key from the standard display takes you to the ”Connection quality
detail display. It contains additional connection information (except in "scan" and
"srch" status) in the 2nd line:
Fig. 26 2nd line of the ”Connection quality” detail display in "Look Around Mode"
4:
Selected antenna of the test radio unit:
“i” : Internal antennas, antenna diversity switched on
e” : External antennas, antenna diversity switched on
“i1” : Internal antenna 1, antenna diversity switched o
“i2” : Internal antenna 2, antenna diversity switched o
e1”: External antenna 1, antenna diversity switched o
e2”: External antenna 2, antenna diversity switched o
Displayed when more than 99 CRC errors have been registered
2. line: Detail display of connection quality
Filtered eld strength display (RSSI)
Counter of the CRC errors (0..99) (CRC = Cyclic Redundancy Check
(can be reset with the ”#” key)
Field strength minimum since the connection was established
(can be reset with the ”#” key)
Field strength minimum of the last couple of measurements

Other manuals for Aastra 400 Series