DECT Measuring Device ME-8 (test kit)
61
Planning Aastra 400 DECT systems as of R1.0
syd-0457/1.0 – R1.0 – 10.2012
Note:
The "always" mode should be selected only in exceptional cases; the
battery capacity is quickly used up when the display backlighting is
continually on.
Handover:
To facilitate measuring out a DECT system, the call transfer (handover) to another
radio unit can be switched on and off. The status is displayed as ”X” or ”H” in the 3rd
line in "Look Around Mode" (see Fig. 24). The setting is not stored. After entering
"Look Around Mode", handover is always switched off.
1. Press the ”M” key in ”Look Around Mode” until "Handover" appears
2. Press Foxkey "Handover":
The status changes from Off (”X”) to On (”H”)
3. Press Foxkey "Handover" again:
The status changes from On (”H”) to Off (”X”)
Note:
Because in a test system the test radio units do not run synchronously,
no ”Connection handover” is possible.
6. 3. 1. 3 Voice connections via the test radio unit
1)
If the selected system is a test system (T), voice connections can be set up as an
acoustic check of the test radio unit. This is only possible with the test phones,
since it requires special phone software. It is advisable to connect the headsets to
the test phones for this purpose. This enables convenient simultaneous acoustic
and visual checking of the call quality.
Loopback Connection with a test telefon
A loopback connection is a special call connection with a test phone. The send path
is looped back in the test radio unit to the reception path. This enables an acoustic
check of the call quality (crackle interference etc.) with just one test phone.
• Press "": Loopback connection is set up
• Press "" or the h” key: Loopback connection is cleared down
1)
Possible only with a test phone