DECT Measuring Device ME-8 (test kit)
68
Planning Aastra 400 DECT systems as of R1.0
syd-0457/1.0 – R1.0 – 10.2012
Display on the test phone
If the setting "Disp" or "Both" is selected, the following display is visible for
7 seconds for every handover:
[1] For explanations see Fig. 22
[2] For explanations see Fig. 23
[3] For explanations see Fig. 27
Fig. 29 Display of a handover during a call connection
Tip:
The handover is signalled acoustically and/or displayed visually in ”Show
Measurement Mode”. This enables checking the field strength before and
after the handover. In this way the handover behaviour from one radio
unit to the other can be observed with respect to field strength.
Keyboard assignment in "Show Handover Mode"
The keyboard assignment (short and long clicks) in "Show handover mode" is the
same as the normal operation of the cordless phone (see the chapter "Long-clicks
with Aastra DECT cordless phones" in the Aastra 415/430 or Aastra 470 System
Manual). The temporary handover display can be prematurely terminated using
the "C" key.

A6C764E
ED
44D4D
1. line: Icons [1]
2. line: Field strenght and call quality
3. + 4. line: Detail display of “Bearerinformation [3]
Handover display:
H:b. successful "Bearer Handover"
H:c. successful "Connection Handover"
H:bf. ”Bearer handover” failed
H:cf. “Connection Handover" failed