EasyManua.ls Logo

ABB 265GS - Menu Structure

ABB 265GS
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
IM/265Gx/Ax-EN-07 265Gx, 265Ax 57
How the percentage value is shown on the LCD display
Position Display
1st line Percentage value, limits: -25 … 125 %,
2 decimal places
2nd line
1st digit:
Transmission function (see previous table)
2nd digit:
Write protection (see previous table)
7th digit:
%
Bar 2 % increments, from -2 … 100 %,
no hysteresis
7.5.2 Menu structure
The parameters are structured in the form of a menu. The menu consists of a maximum of three
levels.

Table of Contents

Related product manuals