ABB ACS800-17 - Power module replacement (Frame R8 i and up)

ABB ACS800-17
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
127
Power module replacement (Frame R8i and up)
WARNING! Ignoring the following instructions can cause physical injury or death,
or damage to the equipment.
Use extreme caution when manoeuvring an inverter, supply or filter module
that runs on wheels. The modules are heavy and have a high centre of gravity.
They topple over easily if handled carelessly.
Do not use the ramp which is supplied with the drive with heights over 50 mm
(the standard plinth height of ABB cabinets). The ramp is designed for a plinth
height of 50 mm.
Do not tilt!Support the top and
bottom of the module
while removing!
Lift the module by the upper part
only using the lifting hole(s) at the
top!
Extend the support legs outside the
cabinet!
Mind your fingers! Keep fingers away from the
edges of the front flange of the module!
Support the top and
bottom of the module while
replacing!
max 50 mm