The ACS800-37
41
Construction C121 = Marine construction (reinforced mechanical parts and fastening,
marking of conductors [A1], door handles, self-extinctive materials)
C129 = UL Listed – Includes +H358
C134 = CSA Approved – Includes +H358
Resistor braking D150 = Brake chopper(s).
D151 = Brake resistors. Not available in IP54 or IP54R. Not available with
+C129 or +C134.
Filters E202 = EMC/RFI filtering for 1st Environment TN (grounded) system,
restricted (A-limits). Only available for certain types. Not available for 690 V.
Note: EMC/RFI filtering for 2nd Environment (+E200) is standard equipment.
E206 = Sine filter – Not available with +C121 or +C129.
Line options F259 = Earthing switch – Not available with +C129
Cabling H351 = Top entry
H353 = Top exit
H358 = US/UK gland/conduit plate
H359 = Common motor terminal cubicle
Auxiliary voltage G304 = 115 V AC
Cabinet options G300 = Cabinet heaters (external supply) – Not available with +C129 or
+C134
G307 = Input terminals for external UPS-backed auxiliary voltage
G313 = Output for motor heater (external supply)
G317 = Busbar supply conductors
G330 = Halogen-free wiring and materials – Not available with +C129 or
+C134
Language of manuals Rxxx
Refer to ACS800 Ordering Information (code: 64556568 [English]).
Starter of auxiliary
motor fan
M602 = 2.5 … 4 A (1, 2 or 4 pcs)
M603 = 4 … 6.3 A (1, 2 or 4 pcs)
M604 = 6.3 … 10 A (1, 2 or 4 pcs)
M605 = 10 … 16 A (1 or 2 pcs)
M606 = 16 … 25 A (1 pc)
Safety features Q950 = Prevention of unexpected start (Category 3)
Q951 = Emergency Stop, Category 0
Q952 = Emergency Stop, Category 1
Q954 = Earth fault monitoring for IT (ungrounded) system
Q959 = Red-coloured trip pushbutton for external breaker
Special P902 = Customised (specified in Technical appendix on ordering)
P904 = Extended warranty
P913 = Special colour (specified in Technical appendix on ordering)
Selection Alternatives