Chapter 2 TwelvePulse Technology
DCS 600 Manual for 12 Pulse Operation
II F2
2 - 15
12 pulse con-
figuration with
only one main
contactor
Figure 2/17 shows the recommended connection of the necessary
signals. Each converter is connected in a similar way to a single
6 pulse converter.
To perform an emergency operation with only one main contactor a
more detailed investigation is required as the handling of the main
contactor has to be switched over from the master to the emer-
gency converter (slave).
SXOVHSDUDOOHO
VHULDOVHTXHQWLDO
FRQILJXUDWLRQ
<
SXOVH0$67(5
'&6
Motor fans
Converter fans
'&6
SXOVH6/$9(
Figure 2/17