Required consumable
NoteArt. no.Equipment, etc.
Loctite 243, for locking
screws.
3HAB7116-1Locking liquid
Optitemp RB23HAC14807-1Cable grease
Fitting the cable package
Use this procedure to fit the cable package.
Preparations
NoteAction
Move the robot to a comfortable working
position.
1
DANGER
Turn off all:
• electric power supply
• hydraulic pressure supply
• air pressure supply
to the robot, before entering the robot
working area.
2
xx1400000197
Remove the rear cover plate (if not already
removed).
3
Fasten the cable package
NoteAction
DANGER
Turn off all:
• electric power supply
• hydraulic pressure supply
• air pressure supply
to the robot, before entering the robot
working area.
1
Continues on next page
90 Product manual - DressPack/SpotPack IRB 8700
3HAC055802-001 Revision: B
© Copyright 2015-2017 ABB. All rights reserved.
2 Installation
2.4.4.2 Fitting the cable package IRBDP SW6 LI, Lean ID
Continued