Operation Manual / Power2 340-H / High-pressure stage
6 Operation and service / 6.3 Expected replacement intervals
© Copyright 2022 ABB. All rights reserved. HZTL4054_EN Rev.F March 2022
Influencing parameters
The actual values can deviate considerably from the guideline values, for example, due to the
following influences:
¡ Fuel quality and fuel treatment
¡ Load profile (thermal cycling, also number of starts/stops, emergency shutdowns)
¡ Gas inlet temperature
¡ Frequency and execution of turbine and compressor cleaning
¡ Specification of the high-pressure stage
¡ System-specific operating conditions (combustion quality, exhaust gas composition)
¡ Atmospheric humidity after the intercooler.
For bearing parts
¡ Lubricating oil quality (oil filtering, oil condition, oil monitoring)
¡ Load profile (speed, pressure conditions, temperature)
¡ Number of starts/stops
¡ Unbalance of the rotor (degree of contamination).
Page 55 / 114