Product Manual
1HSB435416-2 en Rev 1
LTB 245E1
BLG 1002A
3-pole operation

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ABB SF6 LTB 245E1 BLG 1002A and is the answer not in the manual?

ABB SF6 LTB 245E1 BLG 1002A Specifications

General IconGeneral
Rated Voltage245 kV
Rated Current1002 A
Insulation MediumSF6
ModelLTB 245E1 BLG 1002A
TypeLive Tank Breaker

Summary

Product Manual - Product Description

Design of the circuit-breaker

Details physical construction and main components of circuit-breaker poles.

The circuit-breaker’s gas system

Explains SF6 gas system, pressure, and auto-puffer principle for operation.

Operating mechanism

Describes the motor-charged spring operating mechanism type BLG and its operating cycle.

Standards

Lists compliance with IEC Publication 60056 and ANSI C37 standards for circuit-breakers.

Assembly Instructions

Safety

Outlines critical safety warnings, danger, warning, and caution levels during assembly.

Delivery

Provides guidance on checking delivery correspondence, order, and transport damage.

Assembly Procedures

Covers preparations, frame assembly, pole mounting, and mechanism fitting for the circuit-breaker.

Electrical connections

Details how to connect operational and signal cables to the operating mechanism and earth wire.

Pressurising the poles

Provides instructions for filling circuit-breaker poles with SF6 gas and related safety precautions.

Commissioning

Specifies checks to be performed before commissioning and filling in operating values.

Operating values

Lists typical operating values for the circuit-breaker and operating mechanism.

Operating and Maintenance Instructions

General Information

Introduces the scope of instructions for LTB E circuit-breakers, maintenance types, and overhaul requirements.

Preventative maintenance

Discusses service life, arcing contact maintenance, and tightness checking for the circuit-breaker.

Inspection intervals

Lists checkpoints, tolerances, and recommended inspection intervals categorized by maintenance type.

Lubricants

Oil Recommendations

Lists recommended oils for precision components, bearings, and dashpots with supplier details.

Grease Recommendations

Details recommended greases for various parts like bearings, gears, latches, and contacts with supplier info.

Maintenance Operating Mechanism

Safety Directives

Outlines risks and measures for working on the operating mechanism, including high voltage and stored energy.

Maintenance Procedures

Guides on general maintenance, cleaning, lubrication, and checking specific components like drive units and catch gears.

Overhaul Instructions

Overhaul General Procedures

Lists necessary equipment, safety measures, and preparation steps before starting overhaul.

Dismantling the circuit-breaker

Details procedures for safely dismantling the circuit-breaker and its poles for transport and overhaul.

Contact and puffer replacement

Provides instructions for inspecting and replacing arcing contacts, puffer, and current paths.

Spare Parts - LTB 245 E1

Tools and Lubricants

Lists protective covers, oils, and greases required for maintenance and spare parts, including article numbers.

Spare Parts - Operating Mechanism BLG 1002 A

Drive Unit Parts

Lists available drive unit spare parts with article numbers for different voltage and frequency ranges.

Dashpot Parts

Provides article numbers for closing and opening dashpots for various circuit-breaker models.