Introduction – RS485 interfaces |
9
RS485 interfaces
There are two RS485 interfaces on the top of the eMShome (
A
and
B
) which are used for communication with the
eMH1 Wallboxes. The following specifications apply to the RS485 interfaces:
Requirement for the data cable
Nominal voltage/wire insulation: 300V RMS
Cable cross section: 0.25–1.5mm²
Cable type: rigid or flexible
Recommendation: To do this, please refer to the section on “Data cable recommendations” onpage49.
Requirement for cable installation
In the area for connecting the RS485 interfaces on the eMShome, mechanical means must be provided to ensure
that individual wires of the connecting cable are at least 10mm away from live parts.
The connecting cable must be run separately from the mains cables in the distribution board and on the perma-
nent link.
Connection diagram for RS485 connector
Pin Identification Description
1
A
1
B
VCC Voltage output for supply of external devices, 9 V ± 10%, max. 280mA
2
A
2
B
GND Ground
3
A
3
B
A RS485A
4
A
4
B
B RS485B
A
B
4
3
2
1
4
3
2
1