Page #33 background imageLoading...
Page #33 background image
4-5
FIELD TITLE and DATA ENTRIES EXPLANATION
*60
Trouble Report Code
0 = no report
1st digit non-zero = send report
This will be sent if a zone has a trouble condition.
*61
Bypass Report Code
0 = no report
1st digit non-zero = send report
This will be sent when a zone is manually bypassed.
*62
AC Loss Report Code
0 = no report
1st digit non-zero = send report
Timing of this report is random with up to a 4-hour delay. If AC
restores before the report goes out, there is no “AC RESTORE
report.
*63
Low Bat Report Code
0 = no report
1st digit non-zero = send report
This will be sent when a low-battery condition exists in the system’s
standby battery.
*64
Test Report Code
0 = no report
1st digit non-zero = send report
This is sent periodically to test that the communicator and phone
lines are operational. Frequency of report is set using Scheduling
mode (event 11).
*65
Open Report Code
0 = no report
1st digit non-zero = send report
This is sent upon disarming of the system in the selected partitions.
*66
Arm Away/Stay Report Code
0 = no report
1st digit non-zero = send report
This option allows for independent programming of Away and Stay
reports for each partition, including the common lobby.
NOTE: “OPEN” reports are not sent if the associated closing report
is not enabled.
*67
RF Trans. Low Batt. Report Code
0 = no report
1st digit non-zero = send report
This is sent in the event that a wireless transmitter low-battery
condition exists.
*68
Cancel Report Code
0 = no report
1st digit non-zero = send report
This is sent upon disarming of the system after an alarm condition
was reported.
Restore Report Codes (
70–
76)
FIELD TITLE and DATA ENTRIES EXPLANATION
*70
Alarm Restore Report Code
0 = no report
non-zero = send report
This is sent when the zone that caused an alarm is restored to its
non-faulted condition.
*71
Trouble Restore Report Code
0 = no report
1st digit non-zero = send report
This is sent when a trouble in a zone is restored
*72
Bypass Restore Report Code
0 = no report
1st digit non-zero = send report
This is sent when a zone that has been bypassed is unbypassed.
*73
AC Restore Report Code
0 = no report
1st digit non-zero = send report
This is sent when AC power has been restored after an AC power
outage.
*74
Low Bat Restore Report Code
0 = no report
1st digit non-zero = send report
This is sent when a system low-battery condition is restored to
normal.
*75
RF Xmtr Low Batt. Restore Code
0 = no report
1st digit non-zero = send report
This is sent when a transmitter that previously sent in a “LOW
BATTERY” message has sent a message indicating it no longer has a
low-battery condition.
*76
Test Restore Report Code
0 = no report
1st digit non-zero = send report
This is sent when the Test mode is exited.

Table of Contents

Other manuals for ADT Safewatch Pro 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADT Safewatch Pro 3000 and is the answer not in the manual?

ADT Safewatch Pro 3000 Specifications

General IconGeneral
KeypadsSupports multiple keypads
CommunicationLandline, cellular
Remote AccessVia ADT Pulse (if subscribed)
TypeWired
Power Supplybattery backup
CompatibilityADT Monitoring Services
SensorsDoor/Window, Motion
InstallationProfessional
Backup BatteryYes