12-1
SECTION 12
System Operation
•••••••••••••••••••••••••••••••••••••••
Security Codes
The system supports up to 48 security codes, which can each be assigned one of 5 authority levels.
The authority level determines the functions a particular user code can perform as follows:
Authority Levels
Level Functions
Installer (user 01) perform all security functions except can disarm only if used to arm;
can enter program mode; cannot change hidden installer code (default=6321)
Master (user 02) only one master code per system; can perform all security functions, add/delete
users in either partition, change master code, view event log, set system clock,
program keypad macro, program scheduled events, activate output devices
(triggers/relays)
Part. Programmer same as Master, except add/delete users limited to assigned partition
(user 03/user 33) only, where user 03 = partition 1; user 33 = partition 2
(these users can be assigned different authority levels, if desired)
0-User perform security functions (arm, disarm, etc.) only; cannot add/delete users,
view event log, set system clock or program scheduled events
1-Arm Only arm system only
2-Guest can disarm the system only if it was used to arm the system
3-Duress performs security functions, but also silently sends a duress message to the
central station; reports as zone 92
4-Partition Prog. see Partition Programmer paragraph above; use to assign other user numbers
as partition programmers
Refer to the user guide for procedures on adding/deleting security codes. The following is a brief
description of how to add user codes.
Adding a User Code: Master/Part. Prog. code + [8] + 2-digit user no. + user’s code
Deleting a User Code: Master/Part. Prog. code + [8] + 2-digit user no. + [#] [0]
Assigning Attributes: Master/Part. Prog.
code + [8] + 2-digit user no. + [#] [attribute no.] + value
Attributes:
1 = Authority Level (0-4) [see Authority Level table above]
2 = Access Group (0-8)
3 = Active Partition(s) for this user (1, 2, 3 [common] ); enter partitions consecutively
if more than one and press [#] to end the entries
4 = RF Zone No. (assigns user number to button type zone for arm/disarm)
5 = Open/Close Paging (1 for yes, 0 for no)
† Partition Programmer cannot assign parititions.

Table of Contents

Other manuals for ADT Safewatch Pro 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADT Safewatch Pro 3000 and is the answer not in the manual?

ADT Safewatch Pro 3000 Specifications

General IconGeneral
KeypadsSupports multiple keypads
CommunicationLandline, cellular
Remote AccessVia ADT Pulse (if subscribed)
TypeWired
Power Supplybattery backup
CompatibilityADT Monitoring Services
SensorsDoor/Window, Motion
InstallationProfessional
Backup BatteryYes