Safewatch Pro 3000 Installation Instructions
4-8
Pager Programming Fields
FIELD TITLE and DATA ENTRIES EXPLANATION
*160
Pager #1 Phone No.
Enter up to 20 digits
If you enter fewer than 20 digits, exit by pressing [
] and next field
number. To clear entries from this field, press
160
.
*161
Pager #1 Characters
Enter up to 16 characters
Up to 16 optional characters may be sent as a prefix to the 7-digit
system status code sent to pager #1 (if used). Phone number in field
*160 must have been entered. If fewer than 16 characters, exit by
pressing [
] and next field number. To clear entries from this field,
press
161
.
For example, these optional 16 characters may be composed of the
following:
PIN number (to identify a specific pager to the paging company)
Subscriber account number
(enter # + 11 to send
)
# (enter # + 12 to send #)
Pause (enter # + 13 to allow a 2-second pause)*
Any special character(s) the end user may decide to transmit
* Some paging systems require pause(s) before the prefix.
The format for the 7-digit system status code is defined as follows:
Pager Format: XXX-YYYY where:
XXX = 3-digit event code: 911 = Alarm
811 = Trouble
101 = Opening (disarm)
102 = Closing (arm AWAY)
YYYY = 4-digit user or zone number (depending on type of event).
The first two digits must always be 00, and must be
followed by the 2-digit user or zone number.
Example 1.
Pager displays:
911–0004
This indicates that the system is reporting an alarm (911) caused by
a fault in zone 4 (0004).
Example 2.
Pager displays:
102–0005
This indicates that the system is reporting a closing–system arming
(102) by User 5 (0005).
*162
Pager 1 Reports
0 = No reports sent
1 = Open/close for all users enabled to page
4 = All alarms and troubles
5 = All alarms, troubles, and open/close for
all users enabled to page
12 = Alarms and troubles for zones entered
in zone list 9
13 = Alarms and troubles for zones listed in
zone list 9 and open/close for all users
enabled to page
Enter the types of reports to be sent to pager 1 for each partition.
*163
Pager 2 Phone No.
Enter up to 20 digits
If you enter fewer than 20 digits, exit by pressing [
] and next field
number. To clear entries from this field, press
163
.
*164
Pager 2 Characters
Enter up to 16 characters
See field
161 for explanation of entries. If fewer than 16 characters,
exit by pressing [
] and next field number. To clear entries from this
field, press
164
.
*165
Pager 2 Reports
see pager 1 reports, field *162 for entries,
except use zone list 10.
Enter the types of reports to be sent to pager 2 for each partition.

Table of Contents

Other manuals for ADT Safewatch Pro 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADT Safewatch Pro 3000 and is the answer not in the manual?

ADT Safewatch Pro 3000 Specifications

General IconGeneral
KeypadsSupports multiple keypads
CommunicationLandline, cellular
Remote AccessVia ADT Pulse (if subscribed)
TypeWired
Power Supplybattery backup
CompatibilityADT Monitoring Services
SensorsDoor/Window, Motion
InstallationProfessional
Backup BatteryYes

Related product manuals