4-9
FIELD TITLE and DATA ENTRIES EXPLANATION
*166
Pager 3 Phone No.
Enter up to 20 digits
If you enter fewer than 20 digits, exit by pressing [
] and next field
number. To clear entries from this field, press
166
.
*167
Pager 3 Characters
Enter up to 16 characters
See field
161 for explanation of entries. If fewer than 16 characters,
exit by pressing [
] and next field number. To clear entries from this
field, press
167
.
*168
Pager 3 Reports
see pager 1 reports, field *162 for entries,
except use zone list 11.
Enter the types of reports to be sent to pager 3 for each partition.
*169
Pager 4 Phone No.
Enter up to 20 digits
If you enter fewer than 20 digits, exit by pressing [
] and next field
number. To clear entries from this field, press
169
.
*170
Pager 4 Characters
Enter up to 16 characters
See field
161 for explanation of entries. If fewer than 16 characters,
exit by pressing [
] and next field number. To clear entries from this
field, press
170
.
*171
Pager 4 Reports
see pager 1 reports, field *162 for entries,
except use zone list 12.
Enter the types of reports to be sent to pager 4 for each partition.
*172
Pager Delay Option for Alarms
0 = none 2 = 2 minutes
1 = 1 minute 3 = 3 minutes
This field determines the delay of alarm reports to the pager. This
gives the Central Station enough time to verify the alarm report that
it received, before the dialer attempts to dial the pager.
NOTE: The delay does not reset for new alarms occurring while an
existing pager delay is in progress.
This delay is for ALL pagers in the system.
Miscellaneous System Fields
*173
RF Reporting Options
1 = RF Tamper reports during disarm (1=
enable, 0 = disable)
2 = RF button types send low battery
reports (1= enable, 0 = disable)
8 = RF low battery reports delayed (1=
delayed 28 days, 0 = immediate)
Example: .Entering “10” (8 + 2) will enable button-type transmitters
to send low battery reports, and delay all low battery reports for 28
days.
*174
Clean Me Option
0 = disable
1 = enable
3 - Clean Me reports delayed for 28 days
This is a maintenance feature for ESL 2-wire smoke detectors
on Zone 1. If used, this option limits the number of smoke detectors to
a maximum of 10, rather than 16. To enable the “clean me” feature, a
time response setting of “3” (1.2 seconds) must be entered in
56 Zone
Programming for zone 1.
*175
Up And About Time
0 = none;
1-15 = 1 to 15 hours respectively
This feature requires programming of an Up and About schedule (see
Scheduling
section for details). If no zones are faulted or no key is
pressed within the selected time period during a scheduled Up and
About time window, a report is sent to the central station. This can
serve as a safety feature for elderly, infirm, or disabled persons.
*176
Lack Of Usage Option
1-15 weeks
If the control is not armed within the selected time period, a report is
sent to the central station.
*177
Device Duration 1, 2
0 = 15 secs 6 = 2-1/2 min #+12 = 8 min
1 = 30 secs 7 = 3 min #+13 = 10 min
2 = 45 secs 8 = 4 min #+14 = 12 min
3 = 60 secs 9 = 5 min #+15 = 15 min
4 = 90 secs #+10 = 6 min
5 = 2 min #+11 = 7 min
These entries set the duration for output action options 5 (duration
1) and 6 (duration 2) programmed in
80 Output Function
Programming.
*180
Single Zone Bypass
0 = disable
1 = enable
If enabled, users can bypass only one zone when arming the system.
*181
50/60 Hz AC Operation
0 = 60 Hz
1 = 50 Hz
Select the type of AC power applied to the control.

Table of Contents

Other manuals for ADT Safewatch Pro 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADT Safewatch Pro 3000 and is the answer not in the manual?

ADT Safewatch Pro 3000 Specifications

General IconGeneral
KeypadsSupports multiple keypads
CommunicationLandline, cellular
Remote AccessVia ADT Pulse (if subscribed)
TypeWired
Power Supplybattery backup
CompatibilityADT Monitoring Services
SensorsDoor/Window, Motion
InstallationProfessional
Backup BatteryYes

Related product manuals