14-5
Model Product Enter as
Input Device
Type
Description
5819 Shock
Processor
Transmitter
RF
•
Connects to externally mounted inertia-type shock detector
(not supplied).
•
Has built-in tampered cover switch.
•
Has 3 unique input (loop) codes:
Loop 1: Terminals for a wired, N.C. sensor loop.
Loop 2: For a closed circuit contact loop using the built-in
reed switch in conjunction with a magnet.
Loop 3: Terminals for a wired, closed circuit contact loop.
5819WHS
5819BRS
Shock
Processor
Transmitter
RF
•
Has built-in shock sensor.
•
Has built-in tampered cover switch.
•
Has 3 unique input (loop) codes:
Loop 1: Built-in shock sensor loop wired to TB1 (normally
closed).
Loop 2: For a closed circuit contact loop using the built-in
reed switch in conjunction with a magnet.
Loop 3: Externally wired, closed circuit contact loop
connected to TB2.
5827 Wireless
Touchpad
Uses House ID
only
•
Can be used to turn the burglary protection on and off.
•
Features the same built-in panic functions as wired
touchpads.
•
The touchpad is identified as zone “00” on wired touchpads
when it transmits with a low battery.
5827BD Wireless Two-
Way Touchpad
Uses House ID
only
•
Requires 5800TM Transmitter Module.
•
Operates the system similarly to wired touchpads, including
panic functions.
•
Can indicate system status via its 3 LEDs and sounder.
•
Includes 3 panic keys.
5849 Glassbreak
Detector
RF
•
House ID must also be set.
•
Requires both sound and shock of breaking glass to cause
alarm to be transmitted.
5890
PR Detector
†
RF
Dual-element passive infrared detector/transmitter with built-in
selectable pulse count.
Note:
There is a 3-minute lockout between fault transmissions to
conserve battery life.
5899 Magnets
Package of 4 magnets for use with 5816 and 5817 transmitters.