Adtech CNC Technology Co., Ltd. 7. Program saving & editing
- 24 -
¾ When alarm occurs, please remove the alarm reason. Please note that several alarms may occur at the
same time. Please refer to the alarm info in the Diagnosis menu for details. When the alarms are
eliminated, please press [Reset] to clear the alarm ring.
7.4 Self-diagnosis function
The CNC system may stop even when there is no alarm info, this may be because the system is executing
certain processes. Please check with the self-diagnosis function.
The step of self-diagnosis follows:
⑴ In the main menu, press [Diagnosis] to enter the diagnosis interface;
⑵ Select [Input] to enter the input diagnosis interface, or select [Output] to enter the output diagnosis
interface;
⑶ Output diagnosis: In edit mode, press the direction keys to select the output port, and press [EOB] to
switch the output level of corresponding output port;
⑷ Input diagnosis: When certain input signal is valid, the corresponding area on the screen flashes.