EasyManuals Logo

Adtech CNC9650 User Manual

Default Icon
249 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #174 background imageLoading...
Page #174 background image
ADTECH9 Series CNC Maintenance Manual
- 169 -
Effective time : Instant
Note : This setting is used to calculate the analog output of the controller, and
suppose that the analog of variable frequency control is in linear control
mode;
This method is to set the rotation to this parameter according to the
variable frequency rotation corresponding to analog 10V, and transfer the
rotation directly later, while the controller will output corresponding
analog voltage according to linear scale automatically.
004 Spindle Open Delay
Range : 0~10000
Unit : ms
Authority : Operation admin or higher
Default : 0
Effective time : Instant
Note : Set the delay before next action or operation after forward or reverse
rotation of the spindle.
005 System spindle rotation
Range : 1~24000
Unit : rpm
Authority : Operation admin or higher
Default : 6000
Effective time : Instant
Note : Set the current speed of the spindle.
006 Whether close spindle to execute Auto stop
Range : 0~1
Unit :
Authority : Operation admin or higher
Default : 0
Effective time : Instant

Table of Contents

Other manuals for Adtech CNC9650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Adtech CNC9650 and is the answer not in the manual?

Adtech CNC9650 Specifications

General IconGeneral
BrandAdtech
ModelCNC9650
CategoryControl Systems
LanguageEnglish

Related product manuals