EN
1205. 6755517_02
12
8. TECHNICAL DATA
TECHNICAL DATA MODELS POWER SUPPLY M.U. ANL100 ANL150
COOLING MODE
Cooling capacity Alls Alls Tons 6,57 8,16
Total input power
H Alls kW 8,24 9,48
HP-HA Alls kW 8,99 10,98
Water flow rate Alls Alls gpm 16 20
Evaporator pressure drops H - psi 3,80 3,52
Filter pressure drop H - psi 0,55 0,84
Total pressure drop H - psi 4,35 4,36
Useful head HP-HA - psi 14,65 19,14
HEATING MODE
Heating capacity Alls Alls BTU/h 94755 111850
Total input power
H Alls kW 8,29 9,57
HP-HA Alls kW 9,04 11,07
Water flow rate Alls Alls gpm 21 25
Evaporator pressure drops H - psi 6,38 5,15
Filter pressure drop H - psi 0,96 1,31
Total pressure drop H - psi 7,34 6,45
Useful head HP-HA - psi 10,44 14,94
ENERGY INDEX
EER
H Alls W/W 9,58 10,34
HP-HA Alls W/W 8,78 8,92
COP
H Alls W/W 3,35 3,43
HP-HA Alls W/W 3,07 2,96
Alls Alls BTU/W 16,39 17,73
ELECTRICAL DATA
Imput current on
COOLING
H 220-3-60 A 31,40 36,70
H 460-3-60 A 17,10 19,64
HP-HA 220-3-60 A 34,26 42,51
HP-HA 460-3-60 A 18,66 22,75
Imput current on
HEATING
H 220-3-60 A 31,59 37,05
H 460-3-60 A 17,21 19,83
HP-HA 220-3-60 A 34,45 42,86
HP-HA 460-3-60 A 18,76 22,93
H 220-3-60 A 167,40 192,20
H 460-3-60 A 81,40 94,30
HP-HA 220-3-60 A 171,00 198,40
HP-HA 460-3-60 A 83,40 97,50
MCA
H 220-3-60 A 51,30 60,60
H 460-3-60 A 25,50 31,80
HP-HA 220-3-60 A 54,90 66,80
HP-HA 460-3-60 A 27,50 35,00
MOP
H 220-3-60 A 70,00 80,00
H 460-3-60 A 35,00 45,00
HP-HA 220-3-60 A 75,00 90,00
HP-HA 460-3-60 A 35,00 45,00
HEATING (AHRI CONDITIONS)
COOLING (AHRI CONDITIONS)
SOUND POWER
-
SOUND PRESSURE