Assembly instructions EN CS 8 - CS 12 Date 01.06.2021 Version 4.5 45–56
Maintenance activities and maintenance intervals
9.3.1 Overview of the maintenance points
Fig. 16 Maintenance points Compact Slide (CS 8 and CS 12)
No. Maintenance point Maintenance work
Interval
[On/Off]
Remarks
1
Compact Slide
Cleaning
As required [Off]
-
Clean the compact slide with a dry, lint-free cloth.
- do not spray with water
- Do not use aggressive cleaning agents.
2
Shock absorber*
Check functioning
Monthly [On]
Check function of shock absorbers, replace if necessary
replacing after max. 5 million load cycles
3
Compact Slide
Check
Monthly [On]
-
Acoustic control for unusual noise generation
Incorrectly adjusted, missing or defective shock absorbers impair the function
of the module and can lead to its destruction!
*Shock absorbers and stop screws must be checked regularly for correct
function and replaced if necessary. We recommend replacing the shock
absorbers after max. 5 million load cycles.