EasyManuals Logo
Home>Agilent Technologies>Inverter>33250A

Agilent Technologies 33250A User Manual

Agilent Technologies 33250A
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #320 background imageLoading...
Page #320 background image
320
Chapter 8 Specifications
Agilent 33250A Function / Arbitrary Waveform Generator
8
WAVEFORMS
Standard Waveforms: Sine, Square, Ramp,
Pulse, Noise, Sin(x)/x,
Exponential Rise,
Exponential Fall,
Negative Ramp,
Cardiac, DC Volts
Arbitrary Waveforms
Waveform Length: 1 to 64K points
Amplitude Resolution: 12 bits (including sign)
Repetition Rate: 1 µHz to 25 MHz
Sample Rate: 200 MSa/s
Filter Bandwidth: 50 MHz
Non-Volatile Memory:
Four 64K waveforms
1
FREQUENCY CHARACTERISTICS
Sine: 1 µHz to 80 MHz
Square: 1 µHz to 80 MHz
Ramp: 1 µHz to 1 MHz
Pulse: 500 µHz to 50 MHz
Noise (Gaussian): 50 MHz bandwidth
Arb: 1 µHz to 25 MHz
Resolution: 1 µHz;
except pulse, 5 digits
Accuracy (1 year):
2 ppm, 18°C to 28°C
3 ppm, 0°C to 55°C
SINEWAVE SPECTRAL PURITY
Harmonic Distortion
Total Harmonic Distortion
DC to 20 kHz: < 0.2% + 0.1 mVrms
Spurious (non-harmonic)
3
DC to 1 MHz: -60 dBc
1 MHz to 20 MHz: -50 dBc
20 MHz to 80 MHz: -50 dBc + 6 dBc/octave
Phase Noise (30 kHz band)
10 MHz < -65 dBc (typical)
80 MHz < -47 dBc (typical)
SIGNAL CHARACTERISTICS
Square Wave
Rise / Fall Time: < 8 ns
4
Overshoot: < 5%
Asymmetry: 1% of period + 1 ns
Jitter (rms)
< 2 MHz: 0.01% + 525 ps
> 2 MHz: 0.1% + 75 ps
Duty Cycle
< 25 MHz: 20.0% to 80.0%
25 MHz to 50 MHz: 40.0% to 60.0%
50 MHz to 80 MHz: 50.0% (fixed)
Pulse
Period: 20.00 ns to 2000.0 s
Pulse Width: 8.0 ns to 1999.9 s
Variable Edge Time: 5.00 ns to 1.00 ms
Overshoot: < 5%
Jitter (rms): 100 ppm + 50 ps
Ramp
Linearity: < 0.1% of peak output
Symmetry: 0.0% to 100.0%
Arb
Minimum Edge Time: < 10 ns
Linearity: < 0.1% of peak output
Settling Time: < 50 ns to 0.5% of
final value
Jitter (rms): 30 ppm + 2.5 ns
_______________
1
A total of four waveforms can be stored.
2
Harmonic distortion at low amplitudes is limited by
a -70 dBm floor.
3
Spurious noise at low amplitudes is limited by
a -75 dBm floor.
4
Edge time decreased at higher frequency.
< 3 Vpp
2
> 3 Vpp
DC to 1 MHz:
1 MHz to 5 MHz:
5 MHz to 80 MHz:
-60 dBc
-57 dBc
-37 dBc
-55 dBc
-45 dBc
-30 dBc

Table of Contents

Other manuals for Agilent Technologies 33250A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 33250A and is the answer not in the manual?

Agilent Technologies 33250A Specifications

General IconGeneral
BrandAgilent Technologies
Model33250A
CategoryInverter
LanguageEnglish

Related product manuals