agria Two-Wheel Tractor 3400; 3400 KL 47
Battery
There is no dry pre-charging of batteries on
the new machines or trailers. Therefore the
battery must be filled with accumulator acid
and charged (charging current =1/10 of bat-
tery capacity).
Starter Switch
The ignition start switch (34) for electric starter
has 3 settings
0 = Charging current off, key removable
I = Operation
= Start position,
ignition key automati-
cally goes into operating position „I“
I
Warning: Do not set ignition start switch
to “0” while the engine is running. This
can damage the charging regulator.
Warning Signal
A beeper (35) is fitted as a battery charge
indicator.
The warning signal sounds when ignition key
is in position “I” and the engine is at a standstill,
and goes out as soon as the engine runs and
the generator starts charging the battery.
It also goes out when the ignition key is in
position or is removed.
If the warning signal sounds while the engine
is running, the generator does not charge the
battery correctly - Check fuses.
è - Serviceç
3400 D E-Starter
32 Socket
33 Battery
34 Starter switch with key
35 Battery charge control Beeper
3. Devices and Operating Elements
Diesel Engine / E-Starter Version
3
32
33
34 35