Edition 02.97 Power Mower 5400 37
4. Commissioning and Operation
Switching off Petrol
Engine
l
Move speed control lever to idling gas
position and let engine run idle for
approx.1/2 minute.
l
Move engine-off-switch to position
“0”.
l
Close fuel tap (both fuel taps for 2-
stroke-engine).
I
Note: The engine-off-switch
(B/1) also serves as emer-
gency off-switch. If necessary,
bring switch into position “0” to turn en-
gine off.
I
For longer periods of no opera-
tion, do not switch off engine
with engine-off-switch, but close
fuel tap (both fuel taps for 2-stroke-
engine) and let engine run until it slowly
comes to a complete stop due to lack
of fuel. This ensures that carburetor is
empty and no resin residue can deposit.
W
Secure mower against unau-
thorized use – disconnect
spark-plug connector.
6
30 sec