8 ProHood Capture Hoods PH730/PH731
Table 2: List of Optional Hood and Frame Kits
Item
Part No.
1 ft 4 ft (305 mm 1220 mm) fabric hood and frame kit
801200
2 ft 4 ft (610 mm 1220 mm) fabric hood and frame kit
801201
1 ft 5 ft (305 mm 1525 mm) fabric hood and frame kit
801202
3 ft 3 ft (915 mm 915 mm) fabric hood and frame kit
801203
16 in. 16 in. (406 mm 406 mm) fabric hood and frame kit
801209
5.25 in. 4 ft (133 mm 1220 mm) fabric hood and frame kit
801210
28 in. 28 in. (710 mm 710 mm) fabric hood and frame kit
801211
28 in. 50 in. (710 mm 1270 mm) fabric hood and frame kit
801212
1 ft 4 ft (305 mm 1220 mm) and 2 ft 4 ft (610 mm 1220 mm) fabric hood
and frame kit
801206
1 ft 5 ft (305 mm 1525 mm) and 3 ft 3 ft (915 mm 915 mm) fabric hood
and frame kit
801207
8 in. 22 in. (205 mm 560 mm) BSC fabric hood, frame, poles, and stand kit
801204
10 in. 22 in. (255 mm 560 mm) BSC fabric hood, frame, poles, and stand kit
801205
The BSC hood kits are used to certify Class II bio-safety cabinets by taking direct in-flow measurements
for NSF compliance.
Please complete the registration card included with this product and mail it promptly. The card allows us
to inform you of product updates. If you prefer, register through the TSI web site.
Preparing the Instrument for Use
Before you can use the Electronic Balancing Tool, you must decide on a power source.
Power the Micromanometer with the AC Adapter
The AC adapter can be used to power the instrument or to charge the NiMH batteries when the DIP
switch in the battery compartment is set to NiMH. If the DIP switch is set to Alkaline, and the AC power
adapter is connected then the batteries will be bypassed and the meter will be powered by the AC
adapter. Be sure to provide the correct voltage and frequency, which is marked on the back of the AC
adapter.
Power the Micromanometer with Batteries
The micromanometer is designed to operate with either alkaline or NiMH rechargeable batteries. Battery
life will be shorter if NiMH batteries are used. For your convenience, four NiMH batteries are included with
the instrument. If NiMH batteries are used the DIP switch will need to be changed. Refer to the next
section on setting the battery selection switch.
Note
The four NiMH batteries included with the instrument will need to be charged prior to use. Charge
time is 4 hours.
Carbon-zinc batteries are not recommended due to the danger of battery acid leakage.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Airflow Instruments ProHood PH731 and is the answer not in the manual?

Airflow Instruments ProHood PH731 Specifications

General IconGeneral
BrandAirflow Instruments
ModelProHood PH731
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals