Use and Maintenance Manual - XP - XLP Series
5.6.5 Battery charger socket (E)
Models equipped with a built-in high frequency battery charge are provided with this socket to connect the battery charger to the
mains (for more detailed information read the paragraph concerning battery charge).
5.7 Machine start-up
To start the machine the operator shall:
- Unlock the stop button on the ground control panel by pulling it to the outside;
- From the platform control panel, lock the emergency stop button by turning the key 1/4 of turn clockwise.
At this point the functions can be performed by thoroughly following the instructions given in the previous paragraphs.
To start-up the machine, the stop button of the ground control panel must be activated (pulled outwards).
5.8 Machine stop
5.8.1 Normal stop
During the normal stop of the machine, if you release the controls, the operation is stopped.
5.8.2 Emergency stop button
Should it be necessary, the operator may immediately stop all machine functions on both platform and ground by pressing the
previously described stop buttons.
To resume the operations:
- On the platform control panel turn the key of the emergency stop button by a ¼ of turn clockwise.
- From the ground control panel pull the stop button outwards.