Use and Maintenance Manual - XP - XLP Series
Page 34
Connect to the power mains having the following features:
- Power voltage 230V ± 10%
- Frequency 50÷60 Hz
- Activated grounding line.
- Working protection devices according to current standards in force.
- Do not use extension leads exceeding 5 metres to connect to the mains.
- Use a cable of suitable section (min 3x2.5 mm
2
).
- Do not use rolled-up cables.
5.11 End of work
After stopping the machine according to the instructions given in the previous paragraphs, you are advised to:
- Always set the machine to rest position.
- Press the emergency stop button on the platform control panel and remove the key from the push-button station to prevent
unauthorized persons from operating the machine.
- Press the emergency stop button of the ground control panel.
- Recharge the battery according to the instructions given in section "Maintenance".