Use and Maintenance Manual - XP - XLP Series
7.2 Machine cleaning
To clean the machine use non-pressurized water jets after properly protecting the following parts:
- The control panel (both platform and ground)
- All electric boxes and electric devices in general.
- The electric motors.
Do not use pressurized water jets (high-pressure cleaners) to clean the machine.
After washing the machine, always:
- Dry the machine.
- Check integrity of plates and stickers.
- Lubricate the articulated joints equipped with greaser and the sliding ways.
7.3 General maintenance
Below are listed the main maintenance jobs to be done and the relevant schedule (the machine features an hour meter).
Screw tightening (paragraph "Various adjustments”)
After the first 10 working hours
Oil level check in hydraulic tank
After the first 10 working hours
State of the battery (charging cleaning)
Deformation of tubes and cables
Articulated joints greasing
Oil level check in hydraulic tank
Emergency devices efficiency check
Electric connections check
Hydraulic connections check
Periodic operation check and structure visual check
Screw tightening (paragraph "Various adjustments”)
Inclinometer operation check
Calibration check of pressure relief valve
Pedal braking system efficiency check
Automatic braking system efficiency check
M1 microswitch operation check
Total oil change in hydraulic tank
Hydraulic filter replacement
IT IS NECESSARY
TO SEND THE MACHINE TO THE MANUFACTURER FOR A COMPLETE CHECK
FOR A COMPLETE CHECK.