CONTR-OUT (Port degrade - wavelength tracker detection
failure)
The Wavelength Tracker on this card has detected an internal DSP fault. The Wavelength
Tracker information generated may be inaccurate. Channels may be declared absent
and/or detected channel powers for this channel instance may not accurately represent the
actual channel power.
Severity Minor
Service affecting? No
Applicability AHPHG, AHPLG, ALPHG, ALPFGT, AM2017B, AM2125A,
AM2125B, AM2325B, CWR, OSCT
Note: Until this alarm is cleared, wavelength tracking information for the detect
points on the card are invalid.
Corrective Action
NOTICE
Service-disruption hazard
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure “Reseating a Card” (p. 3-19).
If
there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Perform a warm reset of the card.
CLI config card card type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
2
Perform a cold reset of the card.
Note: Refer to Caution at the beginning of this procedure.
CLI config card card_type shelf slot reset cold