DBUNSYNC
DBUNSYNC (The active and standby Main EC databases are not
synchronized)
The database on the active and standby equipment controllers are not in sync.
Severity Major
Service affecting? No
Applicability SYSTEM
Corrective Action
At the end of each step wait to see if the fault clears. If it does not, go to the next step.
...................................................................................................................................................................................................
1
Perform a warm reset of the standby controller.
CLI config card card_type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
2
Contact your next level of support.
DEGOTU
DEGOTU (Signal Degrade - OTU)
The DEGOTU condition is raised when a high B1 error rate is detected on the OTU2/3/4
input line or client port.
Trouble-clearing procedures
DBUNSYNC
DBUNSYNC (The active and standby Main EC databases are
not synchronized)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-68
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
E ND OF STEPS
...................................................................................................................................................................................................