HLDOVRSYNC
HLDOVRSYNC (System timing is in autonomous holdover
synchronization mode)
The OT port has detected a HLDOVRSYNC at the SYNC layer. A SYNC detects
HLDOVRSYNC when system timing is in autonomous holdover synchronization mode.
Severity Not alarmed
Service affecting? No
Applicability SYNC
Corrective Action
...................................................................................................................................................................................................
1
Check all references.
CLI show card 11dpe12e
shelf/slot
synce lineref
{1-4}
WEBUI Select the 11DPE12E card in the Equipment Tree.
Select LINEREF {1-4}.
HWNOTSUPPORTED
HWNOTSUPPORTED (Hardware not supported for current
configuration)
The HWNOTSUPPORTED condition is raised during insertion of an Equipment
Controller in slots 1 or 18, when R1.0.5 software active is detected on the 1830 PSS-32.
Severity Major
Service affecting? Yes
Applicability ECb
Trouble-clearing procedures
HLDOVRSYNC
HLDOVRSYNC (System timing is in autonomous holdover
synchronization mode)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-112
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
E ND OF STEPS
...................................................................................................................................................................................................