MAN (Manually caused abnormal condition - port in
maintenance)
Severity Not alarmed
Service affecting? No
Applicability 112SCA1, 112SCX10, 11STAR1, 11STMM10, 11STGE12,
AM2017B, AM2325B, AHPHG, AHPLG, ALPHG, ALPFGT,
43STA1P, 43STX4, 43STX4P, 4DPA2, 4DPA4, CWR8, MVAC,
OPS, OSCT, RA2P, SFC, SFD, SVAC, WTOCM
Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Manually place the port in service using the following command:
CLI config interface
<shelf slot port>
state up
MAN (Logical removal performed on a timing reference)
The MAN condition occurs when the OT port has detected a MAN at the LINEREF layer,
which indicates that a logical removal was performed on a timing reference.
Severity Minor
Service affecting? No
Applicability LINEREFSYS
To clear the condition, check with the assigning of connection between the LINEREF and
the physical port.
Trouble-clearing procedures
MAN
MAN (Manually caused abnormal condition - port in
maintenance)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-180
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
E ND OF STEPS
...................................................................................................................................................................................................